customized chemical hose compatibility

Appliion Data A Chemical Compatibility Chart

A-19 EATON Industrial Hose and Tubing Master alog E-HOOV-MC003-E1 Septeer 2009 A Appliion Data Chemical Compatibility Chart WARNING – This information provides guidelines for the safe use of Eaton Industrial Hose and Tubing. The informa- tion shown here was gath-ered through testing, and is accurate for controlled conditions (at 70°F unless …

Chemical Resistant Hose | Chemical Hose Compatibility Tool

10/7/2012· The most common asselies fabried by FlexFit Hose are PTFE lined hose with a 304 SS outer braid for reinforcement. 316L SS hose fittings and 304 SS hose ferrules. If your specific chemical, gas or granulate is not listed in the chemical hose compatibility tables, please send it to us via our Contact Us form and we will help you determine

Continental Prospector Custom Hose Assely - Chemical Hose

Continental Prospector Custom Hose Assely. Shipping calculated at checkout. A significant improvement to our chemical hose line. It handles the majority of common industrial chemicals in pressure, gravity flow, and suction service. Universal hose with static dissipating UHMWPE liner for multiple chemical, pharmaceutical and cosmetic appliions.

Fitting Threading Types and Compatibility - New-Line Hose

American Standard Fire Hose Thread (1" National Hose Thread is Chemical Hose Thread, also known as Booster Hose Thread) 1" Male NH (NST) with 1" NH (NST) 1" NH (NST) with 1" Male NH (NST) 1" Thread is used on both 3/4" hose and 1" hose. Not compatible with other systems: Washer Washer: GHT: Garden Hose Thread: Male GHT with GHT

Composite Hose Chemical Resistance Chart

Chemical hose users are cautioned that this Chemical Resistant has be developed from generally accepted industry standards. The ratings listed beneath each Elastomer are the base ratings for the chemical listed. This rating is based on the appliion temperature not exceeding 70ºF (21.1ºC) unless otherwise specified. The degree an Elastomer will resist the effects of a …

Chemical Hose - NovaFlex Group

Compatibility information is available from Novaflex. If no data exists, it is the users responsibility to determine if the hose is compatible with the chemical to be transferred. Never use Novaflex 4700 above the ratings listed by Novaflex. Part No. I.D. O.D Plies R (in) Vacuum Hg WP psi WT LBS/FT 4700CU-07500-00 ¾ 1.20 2 3.5 29” 250 0.58 4700CU-01000-00 1 1.55 2 4 29” …

Hoses for Filling Equipment USA | Teflon Hoses and Fittings

A leader in quality hose and fittings, FlexFit Hose offers customized PTFE hoses. These stainless braided Teflon hose asselies are fabried with 316L stainless steel fittings manufactured in-house on CNC Swiss machines. Improve the performance of your manufacturing equipment by buyingthese flexible and durable PTFE hoses. We can customize orders …

Verderflex Chemical Compatibility Guide

Chemical Compatibility Guide Choosing the best hose and tube for your appliion. Verderflex Tube Selection Choosing the best tube for your appliion The tube is the heart and soul of any peristaltic pump: a poorly selected tube will result in frequent tube changes and increased overall cost of ownership of any equipment. Conventionally, tube size is stated as Internal Diameter …

Chemical Resistance Chart | Texcel

NOTE: Chemical resistance charts are only a guide and should be used as such. The degree of resistance of an elastomer to a material depends upon variables such as temperature, concentration levels, working pressure, flow velocity, duration of use, among other variables. The compound should be tested under actual service conditions to ensure compatibility.

Chemical Compatibility - Custom Molded Rubber Products

COMPATIBILITY CHART Chemical Natural Rubber SBR, GRS Butyl EPR, EPT, EPDM Buna-N, Nitrile, NBR Hydrin Neoprene Hypalon Urethane, Polyurethane Polysulfide Silicone Fluorosilicone Fluoro Elastomers LEGEND A - RECOMMENDED B - MINOR TO MODERATE EFFECT C - MODERATE TO SEVERE U - UNSATISFACTORY BLANK - INSUFFICIENT DATA …

Chemical Resistance Chart - Goodall Hoses

This chemical resistance section is presented by Goodall Rubber Company to assist users in their search for the proper compound for a given appliion. While the information is presented in good faith, no guarantee, expressed or implied, can be given as to the accuracy of these ratings. Chemical Resistance charts Oilfield chemical transfer hose. …

RUBBER HOSES - INDEX

Click on Hose Codes to Be Linked to That Page Chemical Compatibility Tables Commence page 59 Page Group Product Codes Construction Normal Usage Features & Benefits (See main Specifiion pages for details and Approvals) 37 WB1000 Water Blast Hose Very high constant pressure hose for water scaling systems. Suitable for passage of water and aqueous solutions …

Industrial Hose Products/List Prices June 3, 2002

Industrial Hose Chemical Resistance Table 39496-000 January 1, 2003 Supersedes 39496-000 June 3, 2002 ® The world’s most trusted name in belts, hose and hydraulics. 143 ® Contact Denver Product Appliion for recommendations for chemicals not listed. Gates Hose / Polymers Couplings / Adapters Phone (303) 744-5070 1 = Preferred - Constant Contact 2 = Acceptable - …

Chemical Compatibility for Hose - RYCO Hydraulics

65 rows· Chemical Compatibility Chart. The following Chemical Compatibility Chart is for guidance only. In all cases, testing is advised to determine the appliion suitability. Material for Couplings and Adaptors must also be compatible – refer to RYCO Hydraulics Technical Department. Specified resistance applies only at room temperature unless

Chemical Resistance Table - Parker Hannifin

polluting chemical products or when using the hose at elevated pressures and/or temperatures. Continuous use at the highest allowed pressures and temperatures dramatically reduces the service life of a rubber hose. After use hose must be emptied out and washed down. Many chemical products can cause severe injuries to people or damage to property, or risks of …

200 different types of composite hoses l Gutteling

Our composite hoses are produced with an internal and external wire of Stainless Steel 316, Galvanized Steel, Aluminum or special coated Steel. Depending on the chemical compatibility we can produce our hoses with a Polypropylene, PTFE or Hostaflon lining. For special appliions we can also provide high and low temperature resistant layers. Custom made …

TABELLA DI RESISTENZA CHIMICA A 23°C

Chemical compatibility do not imply low permeation. Contact the Technical Service for information regarding permeability. The hoses are not suitable for medical and aeronautical on board appliions. Lo scopo di questa tabella di resistenza chimica è fornire un utile strumento per la selezione del tubo corretto per le diverse applicazioni. I dati forniti provengono da prove …

Chemical Hoses – Industrial Suction & Discharge Hoses – Eaton

Every chemical hose features permanent branding for quick and easy identifiion Unique design permits easy, safe handling of the hose 4:1 safety factor on select hoses (burst: working pressure), exceptional aging, weathering and heat resistance result in …

Chemical Resistance Guide - Goodall Hoses

The compatibility score disregards potential reaction between the selected chemicals. Legend. 1 May be used for continuous service; 2 May be used for intermittent service; 3 Insufficient data, contact customer services; 4 Do not use; Chosen chemicals. Change selection. Select your hoses for further information in the next step. tekno 20°c 68°f. select for more details; …

UHMWPE Ultra-High Molecular Weight Polyethylene Chemical Hose

Universal hose with static dissipating UHMWPE liner for multiple chemical, pharmaceutical and cosmetic appliions. Widely used in the food and beverage industry with hygienic / sanitary products and foodstuffs. Suitable for most liquids, high viscous and powdery materials. Refer to our chemical resistance chart for compatibility. Open steaming at 288°F (142 °C) for …

Chemical Resistance Chart for Hoses - New-Line

Chemical Resistance Chart for Hoses. Use this chart to choose hose and fittings based on the material being conveyed. Please call us at 1-800-661-2208 if you have any questions.

compounds incorporated in Parker hose with the chemicals

Chemical Guides IntroductionThe Chemical Guides in this section are offered as a general indiion of the compatibility of the various Chemical Guides compounds incorporated in Parker hose with the chemicals, fluids and media listed. The basis for the ratings includes actual service experience, the advice of various polymer suppliers, and the considered opinion of our …

Chemical Resistance Chart - Continental Industry

CONTI® CHEM Chemical hoses 2 use (column ‘DE’) or short-term use (column ‘KE’). Depending upon dynamic working stress, medium purity, frequency of media change and temperature the resistance data of the lining material may vary. ContiTech hoses are suitable for use up to the maximum temperature limit stated in the chart for both permanent and short-term …

Select the Right Corrugated Metal Hose | Hose Master

Machine Braided Hose – Hose Master weaves the braid directly onto the hose ensuring that the braid fits tightly against the hose, preventing potential hose deformation or squirm. Selecting a Hose: When selecting a hose, you must consider three variables: pressure carrying capability, flexibility, and chemical compatibility.

TITANFLEX® MODIFIED XLPE CORRUGATED CHEMICAL SUCTION …

If no data exists, it is the user''s responsibility to determine hose/chemical/ temperature compatibility. All critical appliions should be tested. • At operating temperatures of 125°F and above, only permanently attached couplings should be installed. At any operating temperature, couplings attached with bands or clamps may reduce the working pressure of the hose …

Chemical Resistance Ratings For Gates Hose Polymers

to assure chemical compatibility for critical appliions. For specific information, contact Gates Hose/ Connector Product Appliion, Denver, Colorado. How to Use the Chemical Resistance Table 1. Chemicals are listed alphabetically. 2. Find the hose, coupling and adapter material type that has a resistance rating of "1" or "2" (See Rating Scale). 3. Find hose(s) with compatible …

Chemical Resistance | Hose and Fittings Source

Hose and Chemical Table. The Chemical Guides in this section are offered as a general indiion of the compatibility of the various compounds incorporated in Parker hose with the chemicals, fluids and media listed. This is information is available to the public provided by Parker Industrial Hose in alog 4800 and re-presented here by HoseandFittings. The basis for …

Rubber Hose Chemical Resistance Chart - NovaFlex Group

Chemical hose users are cautioned that this chemical resistant information has been developed from generally accepted industry standards. The ratings listed beneath each resin are the base ratings for the chemicals listed. This rating is based on the appliion temperature not exceeding 70º F (21.1º C) unless otherwise specified. The degree to which a resin will resist the effects of …

Eaton Chemical Hose Products | Anderson Process

Eaton Chemical Hoses come in a bunch of different configurations that have been specifically designed for a variety of appliions. There are suction and discharge, discharge and specialty hoses to choose from. Temperatures range from -45°F to 275°F and you''ll find hoses constructed with tubes consisting of nylon, EPDM, PVC/Polyurethane, CPE

Industrial Hose Chemical Resistance Charts

Further testing is recommended to determine compatibility of the chemical with the product. Caution Unless otherwise specified, the ratings applied to tube stocks are based on fully concentrated or saturated solutions at 100˚F (37.8˚C) under normal service conditions. Note Hose ratings are for the effect on the polymer only. The degree of resistance of a rubber compound …